Availability: | |
---|---|
JBC (1kV) series puncture clamp are suitable for branches and the connection of insulated overhead lines of 1kV and below.
JBC (10kV) series puncture clamp are suitable for the connection of branches from the main line in insulated overhead lines or for the connection of bridging wires between two voltage sections.
The design enables hot line installation. Equipped with shear head screw. Comply with UNE 21021, NFC 33020, ASTM G26, ASTM B117, ASTM G154, ASTM G155, ANSI C119.4.
1. Suitable for aluminum and copper conductors.
2. Sealed structure, corrosion resistant, long service life.
3. Low contact resistance, low temperature rise of wire terminals.
4. Different diameter conductor connection, wide range of applications.
5. Excellent insulation performance, 1kV dielectric strength greater than 4kV, 10kV dielectric strength greater than 18kV.
Be applicable Voltage (kV) | Model | Main | Branch wire | Number of | Torque | Dimensions(mm) | ||
H | B | L | ||||||
1kV | JBC15-25/1.5-10 | 1.5-25 | 1.5-10 | 1 | 13 | 45 | 27 | 60 |
JBC16-70/4-15 | 16-70 | 4-25 | 1 | 25 | 52 | 52 | 85 | |
JBC16-70/16-70 | 16-70 | 16-70 | 1 | 25 | 52 | 52 | 85 | |
JBC16-95/4-35 | 16-95 | 4-35 | 1 | 25 | 60 | 45 | 85 | |
JBC25-95/25-95 | 25-95 | 25-95 | 2 | 25 | 65 | 56 | 85 | |
JBC50-120/16-50 | 50-120 | 16-50 | 1 | 25 | 56 | 54 | 85 | |
JBC50-120/50-120 | 50-120 | 50-120 | 1 | 25 | 60 | 54 | 85 | |
JBC50-150/6-35 | 50-150 | 6-35 | 1 | 25 | 60 | 45 | 85 | |
JBC50-150/50-150 | 50-150 | 50-150 | 2 | 25 | 67 | 58 | 95 | |
JBC95-240/95-240 | 95-240 | 95-240 | 2 | 25 | 77 | 67 | 95 | |
JBC120-240/25-120 | 120-240 | 25-120 | 2 | 25 | 67 | 63 | 95 | |
JBC120-240/70-120 | 120-240 | 70-120 | 2 | 25 | 78 | 60 | 95 | |
JBC120-240/120-240 | 120-240 | 120-240 | 2 | 25 | 80 | 64 | 95 | |
10kV | JBC10-0 | 10-25 | 10-25 | 2 | 30 | 95 | 73 | 115 |
JBC10-1 | 25-50 | 25-50 | 2 | 30 | 95 | 73 | 115 | |
JBC10-2 | 70-120 | 25-50 | 2 | 30 | 95 | 78 | 115 | |
JBC10-3 | 70-120 | 70-120 | 2 | 30 | 95 | 78 | 115 | |
JBC10-4 | 150-240 | 70-120 | 2 | 30 | 95 | 89 | 115 | |
JBC10-5 | 150-240 | 150-240 | 2 | 30 | 95 | 86 | 115 | |
JBC10-6 | 150-240 | 25-50 | 2 | 30 | 95 | 86 | 115 |
Summary
The insulation sleeve, the puncture blades, the waterproof rubber mat, and the torque screws are the main parts of the insulation puncture clamp. Using a socket wrench, tighten the torque nut on the clamp to join the cable branches of the insulating clamp. First, place the branch cable into the branch cap to identify the location of the main cable branch.The puncture blade's insulation gradually closes up while, at the same time, the metal conductor and cable insulation are punctured by the puncture blade's piercing as its curving sealing ring gradually sticks to them. The torque nut will automatically loosen when the metal body of the puncture insert and the gasket and dielectric grease are in effective contact. Concurrently, this indicates that the installation is finished and the contact points' electrical efficacy and tightness are superb.
JBC (1kV) series puncture clamp are suitable for branches and the connection of insulated overhead lines of 1kV and below.
JBC (10kV) series puncture clamp are suitable for the connection of branches from the main line in insulated overhead lines or for the connection of bridging wires between two voltage sections.
The design enables hot line installation. Equipped with shear head screw. Comply with UNE 21021, NFC 33020, ASTM G26, ASTM B117, ASTM G154, ASTM G155, ANSI C119.4.
1. Suitable for aluminum and copper conductors.
2. Sealed structure, corrosion resistant, long service life.
3. Low contact resistance, low temperature rise of wire terminals.
4. Different diameter conductor connection, wide range of applications.
5. Excellent insulation performance, 1kV dielectric strength greater than 4kV, 10kV dielectric strength greater than 18kV.
Be applicable Voltage (kV) | Model | Main | Branch wire | Number of | Torque | Dimensions(mm) | ||
H | B | L | ||||||
1kV | JBC15-25/1.5-10 | 1.5-25 | 1.5-10 | 1 | 13 | 45 | 27 | 60 |
JBC16-70/4-15 | 16-70 | 4-25 | 1 | 25 | 52 | 52 | 85 | |
JBC16-70/16-70 | 16-70 | 16-70 | 1 | 25 | 52 | 52 | 85 | |
JBC16-95/4-35 | 16-95 | 4-35 | 1 | 25 | 60 | 45 | 85 | |
JBC25-95/25-95 | 25-95 | 25-95 | 2 | 25 | 65 | 56 | 85 | |
JBC50-120/16-50 | 50-120 | 16-50 | 1 | 25 | 56 | 54 | 85 | |
JBC50-120/50-120 | 50-120 | 50-120 | 1 | 25 | 60 | 54 | 85 | |
JBC50-150/6-35 | 50-150 | 6-35 | 1 | 25 | 60 | 45 | 85 | |
JBC50-150/50-150 | 50-150 | 50-150 | 2 | 25 | 67 | 58 | 95 | |
JBC95-240/95-240 | 95-240 | 95-240 | 2 | 25 | 77 | 67 | 95 | |
JBC120-240/25-120 | 120-240 | 25-120 | 2 | 25 | 67 | 63 | 95 | |
JBC120-240/70-120 | 120-240 | 70-120 | 2 | 25 | 78 | 60 | 95 | |
JBC120-240/120-240 | 120-240 | 120-240 | 2 | 25 | 80 | 64 | 95 | |
10kV | JBC10-0 | 10-25 | 10-25 | 2 | 30 | 95 | 73 | 115 |
JBC10-1 | 25-50 | 25-50 | 2 | 30 | 95 | 73 | 115 | |
JBC10-2 | 70-120 | 25-50 | 2 | 30 | 95 | 78 | 115 | |
JBC10-3 | 70-120 | 70-120 | 2 | 30 | 95 | 78 | 115 | |
JBC10-4 | 150-240 | 70-120 | 2 | 30 | 95 | 89 | 115 | |
JBC10-5 | 150-240 | 150-240 | 2 | 30 | 95 | 86 | 115 | |
JBC10-6 | 150-240 | 25-50 | 2 | 30 | 95 | 86 | 115 |
Summary
The insulation sleeve, the puncture blades, the waterproof rubber mat, and the torque screws are the main parts of the insulation puncture clamp. Using a socket wrench, tighten the torque nut on the clamp to join the cable branches of the insulating clamp. First, place the branch cable into the branch cap to identify the location of the main cable branch.The puncture blade's insulation gradually closes up while, at the same time, the metal conductor and cable insulation are punctured by the puncture blade's piercing as its curving sealing ring gradually sticks to them. The torque nut will automatically loosen when the metal body of the puncture insert and the gasket and dielectric grease are in effective contact. Concurrently, this indicates that the installation is finished and the contact points' electrical efficacy and tightness are superb.
Henvcon is eager to explore the future in a way that benefits all parties concerned.