The LF type yoke plate connects separate conductors in twin-connection insulator strings on 330KV high-voltage transmission lines.
1. Typically made from corrosion-resistant, high-strength metals like aluminum alloy or hot-dip galvanized steel.
2. Assemble the plate fittings for connecting the insulator string
3. Superior mechanical strength and performance
4. Long-lasting durability
5. Corrosion-resistant, high-strength
model | Main dimensions (mm) | Specified Failure Load (kN) | Weight(kg) | |||
H | L | b | φ | |||
LF-21-110/400 | 110 | 400 | 16 | 20 | 210 | 8.9 |
LF-21-120/450 | 120 | 450 | 16 | 20 | 210 | 10.5 |
LF-21-120/500 | 120 | 500 | 16 | 20 | 210 | 12.2 |
LF-21-120/600 | 120 | 600 | 16 | 20 | 210 | 14.2 |
LE-25-120/400 | 120 | 400 | 16 | 24 | 250 | 10.0 |
LF-25-120/450 | 120 | 450 | 16 | 24 | 250 | 11.5 |
LF-25-120/500 | 120 | 500 | 16 | 24 | 250 | 12.3 |
LF-25-120/600 | 120 | 600 | 16 | 24 | 250 | 14.5 |
LF-32-120/400 | 120 | 400 | 18 | 26 | 320 | 11.6 |
LF-32-120/500 | 120 | 500 | 18 | 26 | 320 | 14.2 |
LF-32-120/600 | 120 | 600 | 18 | 26 | 320 | 16.7 |
LF-42-120/500 | 120 | 500 | 20 | 26 | 420 | 15.8 |
LF-42-120/600 | 120 | 600 | 20 | 26 | 420 | 18.6 |
LE-64-120/450 | 120 | 450 | 28 | 33 | 640 | 22.0 |
Summary
The LF type yoke plate features a rectangular shape with an oval hole positioned in the center. It facilitates the connection between two separate conductors in a twin-connection insulator string, whether it's a suspension or tension insulator string. Typically, it is installed on overhead high-voltage transmission lines operating at 330KV.
The LF type yoke plate connects separate conductors in twin-connection insulator strings on 330KV high-voltage transmission lines.
1. Typically made from corrosion-resistant, high-strength metals like aluminum alloy or hot-dip galvanized steel.
2. Assemble the plate fittings for connecting the insulator string
3. Superior mechanical strength and performance
4. Long-lasting durability
5. Corrosion-resistant, high-strength
model | Main dimensions (mm) | Specified Failure Load (kN) | Weight(kg) | |||
H | L | b | φ | |||
LF-21-110/400 | 110 | 400 | 16 | 20 | 210 | 8.9 |
LF-21-120/450 | 120 | 450 | 16 | 20 | 210 | 10.5 |
LF-21-120/500 | 120 | 500 | 16 | 20 | 210 | 12.2 |
LF-21-120/600 | 120 | 600 | 16 | 20 | 210 | 14.2 |
LE-25-120/400 | 120 | 400 | 16 | 24 | 250 | 10.0 |
LF-25-120/450 | 120 | 450 | 16 | 24 | 250 | 11.5 |
LF-25-120/500 | 120 | 500 | 16 | 24 | 250 | 12.3 |
LF-25-120/600 | 120 | 600 | 16 | 24 | 250 | 14.5 |
LF-32-120/400 | 120 | 400 | 18 | 26 | 320 | 11.6 |
LF-32-120/500 | 120 | 500 | 18 | 26 | 320 | 14.2 |
LF-32-120/600 | 120 | 600 | 18 | 26 | 320 | 16.7 |
LF-42-120/500 | 120 | 500 | 20 | 26 | 420 | 15.8 |
LF-42-120/600 | 120 | 600 | 20 | 26 | 420 | 18.6 |
LE-64-120/450 | 120 | 450 | 28 | 33 | 640 | 22.0 |
Summary
The LF type yoke plate features a rectangular shape with an oval hole positioned in the center. It facilitates the connection between two separate conductors in a twin-connection insulator string, whether it's a suspension or tension insulator string. Typically, it is installed on overhead high-voltage transmission lines operating at 330KV.